SoR Oscilloscope Tips: Optimizing Measurements and Reducing NoiseThe SoR oscilloscope family offers many advanced features useful for precise measurement in lab, field, and production environments. Getting the best performance from an SoR oscilloscope requires attention to probe technique, grounding, bandwidth and sampling settings, triggering, and post-capture analysis. This article collects practical tips and workflows to help you maximize signal fidelity, reduce noise and interference, and extract accurate measurements.
1. Start with the measurement objective
Before touching knobs, decide exactly what you need to measure: amplitude, frequency, rise/fall time, jitter, spectral content, or encoded data. Your measurement goal drives choices such as timebase, probe type, bandwidth, and whether to use averaging or single-shot capture.
- Amplitude and DC levels: stable timebase, proper probe attenuation, and good DC coupling.
- Fast edges and rise time: highest available bandwidth, shortest probe ground connection, and high sample rate.
- Low-level signals near noise floor: use averaging, grounding best practices, and possibly external preamplification.
- Jitter and timing: long captures with precise triggering and digital demodulation or envelope functions.
2. Probe selection and handling
Probing is often the dominant error source. The right probe, used correctly, reduces loading, preserves bandwidth, and minimizes added noise.
- Use active probes for low-capacitance, high-impedance circuits and passive 50 Ω probes for matched, high-frequency systems.
- Match probe bandwidth to the oscilloscope; avoid using a probe with substantially lower bandwidth than the oscilloscope as it limits overall system performance.
- For high-frequency or high-edge-rate signals, use short ground leads or spring-tip adapters to reduce inductance and ringing.
- Compensate passive probes before measurements using the oscilloscope’s calibration square wave; a miscompensated probe distorts edges.
- Consider differential probes when measuring across floating nodes to avoid ground loops.
3. Grounding and layout practices
Ground loops and poor grounding dramatically increase noise. Small changes to grounding and probe attachment often yield large improvements.
- Connect the oscilloscope chassis and probe ground to a single, solid earth ground when possible.
- Avoid long ground leads on passive probes; use probe ground springs or grounding kits to keep loop area minimal.
- When probing on PCBs, attach to a nearby ground plane or use a ground spring clipped to a via placed close to the test point.
- For sensitive low-level signals, disconnect other nearby noisy equipment or power sources if safe and feasible.
4. Bandwidth, sampling rate, and input coupling
Choosing bandwidth and sample rate settings optimizes noise performance and measurement accuracy.
- Use bandwidth limit filters (e.g., 20 MHz or 100 MHz) to reduce out-of-band noise when the signal contains no high-frequency content.
- Ensure sample rate provides at least 5–10 samples per fastest feature (edges, pulses) for reliable reconstruction. For high-precision edge timing or jitter measurement, oversample as allowed.
- For DC or low-frequency signals, use AC coupling only when you want to remove DC offset; otherwise use DC coupling to retain absolute voltage levels.
- When using probe attenuation (e.g., 10×), set the scope channel to the matching attenuation so displayed measurements are correct.
5. Triggering strategies
Correct triggering isolates the event of interest, reducing unnecessary noise in the capture and making measurements repeatable.
- Use edge triggers for routine waveform capture; set slope and level precisely.
- Use pulse-width, runt, or glitch triggers to capture rare timing anomalies.
- For repetitive signals, use single-shot capture with a pre-trigger percentage to capture the event leading edge.
- Use advanced triggers (e.g., pattern, protocol, or sequence triggers) when dealing with digital buses or bursts to reduce false captures.
- Add hysteresis or noise rejection if unwanted jitter around the trigger level causes unstable triggering.
6. Noise reduction techniques during capture
Combine hardware and software strategies to reduce noise during acquisition.
- Use averaging for repetitive signals; math-based averaging reduces uncorrelated random noise by approximately 1/√N (where N is number of acquisitions).
- Use peak detect or high-resolution modes when capturing short-duration spikes or sparse events; peak detect captures highest/lowest points within sample windows.
- Enable digital filtering sparingly to attenuate known interference bands; beware that filtering alters waveform shape.
- If equipment-generated noise is suspected, try powering instruments from separate circuits or using isolated power supplies to identify coupling sources.
- For low-frequency noise (mains hum), use notch filters or synchronous averaging (triggered to line frequency) to remove ⁄60 Hz components.
7. Post-capture processing and measurement best practices
After capturing data, use the SoR oscilloscope’s analysis tools smartly to extract precise values.
- Use cursors and automated measurement functions (RMS, Vpp, rise time, frequency) but verify with manual cursors for critical results.
- Apply math channels (subtract, divide, FFT) to isolate or transform signals; for example, subtract a reference channel to remove common-mode interference.
- Use FFTs to analyze spectral content — increase FFT window length for better frequency resolution, and apply appropriate windowing (Hann, Hamming) to reduce leakage.
- For jitter and eye-diagram analysis, collect long-duration captures and use dedicated eye/jitter tools to separate deterministic from random jitter components.
8. Specialized tips for reducing specific noise types
- Mains (⁄60 Hz) hum: physically separate signal and power cables, use star grounding, and apply notch or synchronous filters.
- RF interference: add shielding or move antennas/emitters away; use ferrite beads on cables and keep probe loops tight.
- Switching power supply noise: use common-mode chokes, decoupling capacitors near the switching nodes, and probe at test points designed for measurement.
- Ground bounce in digital systems: use local bypass capacitors and probe differential signals where possible.
9. Calibration and maintenance
Regular calibration and proper maintenance keep the oscilloscope and probes performing optimally.
- Calibrate the oscilloscope and probes per manufacturer recommendations; annual calibration is common in professional labs.
- Inspect probes and cables for wear or broken shields; damaged probes can introduce unpredictable noise.
- Keep firmware up to date — manufacturers often improve measurement algorithms and add features.
- Use the oscilloscope’s self-calibration routines before high-precision measurements.
10. Example measurement workflows
-
Measuring a 10 ns rise time signal:
- Use the highest bandwidth channel and a 10× or active probe with short ground spring.
- Set timebase to show several cycles, sample rate ≥5× the inverse of rise time.
- Use single-shot capture with edge trigger; use averaging only if signal is repetitive.
-
Measuring low-level sensor output buried in noise:
- Use DC coupling, high input impedance (active probe), and short probe ground return.
- Enable averaging (start with 16–64 acquisitions).
- Apply low-pass bandwidth limit slightly above signal bandwidth; use FFT to confirm noise reduction.
11. Troubleshooting checklist
- Are probes compensated and channel attenuation set correctly?
- Is the probe ground lead as short as possible?
- Is the channel bandwidth set higher than signal content (or wisely limited for noise reduction)?
- Are triggering settings stable and specific to the event?
- Is there a ground loop or nearby noisy equipment?
- Have you tried differential probing or alternative grounding points?
Conclusion
Optimizing measurements and reducing noise on an SoR oscilloscope is a mix of good probing technique, correct instrument settings, thoughtful grounding, and targeted post-processing. Small changes—shortening a ground lead, matching probe compensation, selecting the right bandwidth—often yield the biggest improvements. With systematic setup and the techniques above, you’ll get cleaner captures and more reliable measurements from your SoR oscilloscope.