How to Create Publication-Quality Graphs in GraphPad PrismCreating publication-quality graphs is about clarity, accuracy, and visual appeal. GraphPad Prism combines statistical analysis with flexible graphing tools, making it a favorite in life sciences and other research fields. This guide walks through best practices and step-by-step instructions to produce figures that meet journal standards.
1. Plan your figure before you start
- Define the message: what single idea should each graph convey?
- Choose the appropriate graph type (scatter, bar, box-and-whisker, violin, Kaplan–Meier, heat map, etc.) based on your data and the story.
- Consider journal requirements (file format, resolution, color usage, font sizes, panel arrangement).
2. Prepare and organize your data
- Clean your dataset: check for missing values, outliers, and correct units.
- Structure your Prism data tables according to the chosen analysis/graph type (e.g., XY table for scatter plots, Column table for bar graphs).
- Use separate data tables for independent experiments or conditions you want to plot together with consistent grouping.
Example data organization:
- Column data: group means and SD/SEM for bar graphs.
- XY data: individual x-y pairs for dose–response or time-course plots.
- Survival data table: for Kaplan–Meier curves.
3. Choose the right graph type and display of variability
- Scatter plots with individual points are best for small sample sizes (n < ~20).
- Bar graphs can be misleading when they hide data distributions—prefer dot plots or box-and-whisker plots when possible.
- Use SD, SEM, or confidence intervals appropriately and label which you used. For most comparative purposes, show 95% CI or SD for clarity.
4. Run appropriate statistics in Prism
- Use Prism’s built-in analyses (t-tests, ANOVA, regression, nonparametric tests) rather than posting p-values without context.
- Check assumptions (normality, equal variance) and select tests accordingly. Prism provides normality tests and multiple comparison corrections.
- Report effect sizes and confidence intervals where possible; p-values alone are insufficient.
Example: For comparing 3 groups with parametric data, run One-way ANOVA → post hoc multiple comparisons (Tukey). For nonparametric, use Kruskal–Wallis → Dunn’s multiple comparisons.
5. Design principles for clarity and readability
- Minimize chartjunk: remove unnecessary gridlines, 3D effects, or heavy shading.
- Use consistent fonts and sizes. Journals commonly require 8–12 pt for axis labels and 10–14 pt for figure text; match journal guidelines.
- Ensure high contrast between data and background. Use color-blind–friendly palettes (e.g., ColorBrewer palettes or Prism’s color-blind options).
- Keep axis ranges appropriate—don’t truncate data misleadingly. If using a broken axis, clearly indicate it.
6. Customize axes, ticks, and labels
- Label axes with units (e.g., “Concentration (µM)”) and include symbols or Greek letters using Prism’s character palette.
- Use a limited number of tick marks; prefer major ticks only for cleaner appearance.
- For log-transformed data, use log scales and label tick values properly (e.g., 10^1, 10^2).
7. Add error bars and annotate significance clearly
- In Prism, add error bars from the data table or choose to display them as mean ± SD/SEM/CI.
- Annotate significance using asterisks or exact p-values. Provide a figure legend that explains the statistical tests and what the symbols mean (e.g., p < 0.05).
- Avoid overcrowding the plot with many asterisks—consider grouping comparisons or using brackets/lines to show which groups were compared.
8. Create multi-panel figures with consistent styling
- Use Prism’s “Arrange Graphs” to combine panels; maintain consistent axis ranges, fonts, and marker styles across panels for comparability.
- Number panels (A, B, C) and provide a concise panel caption in the figure legend explaining each panel.
- Export each panel at high resolution and assemble in a vector-aware layout program (Illustrator, Inkscape) if required by the journal.
9. Export settings for publication
- Export as vector formats (PDF, EPS, SVG) when possible to preserve resolution for lines and text. Use TIFF for raster images at a minimum of 300–600 dpi for color/greyscale figures.
- Set image size to match journal column widths (single column ~85–90 mm, double column ~175–180 mm) and ensure fonts remain legible when scaled.
- Embed fonts or convert text to outlines for PDFs if the journal requires it.
Prism export tip: Use “File > Export > PDF” for vector output, and choose appropriate dimensions and font embedding.
10. Write a concise, informative figure legend
- State what is shown, sample sizes (n), statistical tests used, and definitions of error bars and significance symbols.
- Keep the legend self-contained but concise—readers should understand the figure without searching the main text.
Example legend sentence: “Mean ± SD shown; n = 6 per group. One-way ANOVA with Tukey’s post hoc test: p < 0.05, p < 0.01.”
11. Common mistakes and how to avoid them
- Hiding raw data under bar graphs — show individual points or use box plots when possible.
- Using inappropriate error bars — always state whether bars are SD, SEM, or CI.
- Overuse of colors or patterns — simplify to improve clarity and reproducibility.
- Ignoring journal guidelines — always check specific figure and file requirements before finalizing.
12. Quick workflow checklist
- Plan your figure and check journal specs.
- Organize and clean data in Prism tables.
- Choose correct graph type and display raw data if feasible.
- Run appropriate statistics and annotate results.
- Tidy visual elements: axes, labels, colors.
- Arrange multi-panel figures consistently.
- Export using vector formats or high-resolution TIFF.
- Write a clear figure legend with statistical details.
Creating publication-quality graphs in GraphPad Prism is a balance of sound statistics, clear data presentation, and clean visual design. Following these steps will help ensure your figures communicate results accurately and meet journal standards.
Leave a Reply